INTEGRATION ANALYSIS OF THERMAL AND DAYLIGHT PERFORMANCE THROUGH THE BUILDING ENVELOPE

Authors

  • Alifiano Rezka Adi Walisongo State Islamic University, Semarang http://orcid.org/0000-0001-5600-4332
  • Muhammad Afiq Walisongo State Islamic University, Semarang
  • Didung Putra Pamungkas Walisongo State Islamic University, Semarang

:

https://doi.org/10.9744/dimensi.49.2.87-98

Keywords:

Thermal performance, daylight, simulation, EnergyPlus, Dialux

Abstract

Several strategies in reducing external heat gain sometimes have an impact on limited access to daylight in buildings. Therefore, an integrated study is needed between thermal and daylight performance of the building. This research focuses on building modeling and simulation on one of the buildings at UIN Walisongo Semarang to see these two parameters based on Standard Nasional Indonesia. The thermal performance through OTTV value is simulated using EnergyPlus, while the building daylight is simulated using Dialux. The existing condition showed that the thermal performance is not fully integrated with the building natural lighting. Further simulation is needed through the building envelope engineering. The results showed that the entire room has met the standard of natural lighting while maintaining the OTTV value according to the standard. This condition is the optimal point which represents the integration between thermal and daylight performance of the building.

Downloads

Download data is not yet available.

References

Adi, A. R. (2017). Kajian Konsep Ekologis pada Gedung Perpustakaan Pusat UGM. Jurnal ATRIUM, 3(1), 69-83.

Adi, A. R. (2019). Optimalisasi Pencahayaan Alami pada Ruang Perpustakaan Universitas Islam Negeri Walisongo Semarang. Jurnal Komposisi, 13(1), 35-44.

Adi, A. R., Suryabrata, J. A. & Pradipto, E. (2019). Optimizing Shading Devices Through the Shading Effect of Surrounding Buildings. Jurnal Dimensi, 46(2), 79-86.

Altan, H., Mohelnikova, J. & Hofman, P. (2015). Thermal and Daylight Evaluation of Building Zones. ELSEVIER Energy Procedia, 78, 2784–2789.

Athoillah, M. R. & Biyanto, T. R. (2014). Optimasi Penggunaan Pencahayaan Alami pada Ruang Kerja dengan Mengatur Perbandingan Luas Jendela terhadap Dinding. Jurnal Teknik Pomits, 1(1), 1-6.

Atthaillah, Iqbal, M. & Situmeang, I. S. (2017). Simulasi Pencahayaan Alami pada Gedung Program Studi Arsitektur Universitas Malikussaleh. NALARs Jurnal Arsitektur, 16, 113-124.

Chan, A. & Chow, T. (2014). Calculation of overall thermal transfer value (OTTV) for commercial buildings constructed with naturally ventilated double skin façade in subtropical Hong Kong. Elsevier Energy and Buildings, 69, 14-21.

Edrees, M. B. (2010). Konsep Arsitektur Islami Se-bagai Solusi Dalam Perancangan Arsitektur. Journal of Islamic Architecture, 1(1), 16-20.

Granadeiro, V. (2012). Building Envelope Shape Design in Early Stages of The Design Process: Integrating Architectural Design Systems and Energi Simulation. ELSEVIER Automation in Construction, 32, 196–209.

Gulati, N. (2012). Cost Effectiveness in HVAC by Building Envelope Optimization. Revista AUS, 11, 14-17.

Hui, S. C. (1997). Overall Thermal Transfer Value (OTTV): How to Improve Its Control in Hong Kong. s.l., s.n., 1-11.

Husin, S. N. F. S. & Harith, Z. Y. H. (2012). The Performance of Daylight through Various Type of Fenestration in Residential Building. Elsevier Procedia - Social and Behavioral Sciences, 36, 196-203.

Kirimtat, A., Koyunbaba, B., Chatzikonstantinou, I. & Sariyildiz, S. (2016). Review of Simulation Modeling for Shading Devices in Buildings. ELSEVIER Renewable and Sustainable Energy Reviews, 53, 23-49.

Kustianingrum, D. et al. (2016). Kenyamanan Visual Ditinjau dari Orientasi Massa Bangunan dan Pengolahan Fasad Apartemen Gateway Bandung. Jurnal Reka Karsa, 1-11.

Loekita, S. (2006). Analisis Konservasi Energi Melalui Selubung Bangunan, Dimensi Teknik Sipil, 8, (2), 93–98.

Rattanongphisat, W. & Rordprapat, W. (2014). Stra-tegy for Energy Efficient Buildings in Tropical Climate. ELSEVIER Energy Procedia, 52, 10-17.

Satwiko, P. (2011). Pemakaian Perangkat Lunak Dialux sebagai Alat Bantu Proses Belajar Tata Cahaya. Jurnal Arsitektur KOMPOSISI, 2(2), 142-154.

Saud, M. I. (2012). Pengaruh Konfigurasi Window to Wall Ratio, Solar Heat Gain Coefficient dan Orientasi Bangunan terhadap Kinerja Termal Selubung Bangunan. Yogyakarta: Univ. Gadjah Mada, Program Pascasarjana.

Thojib, J. & Adhitama, M. S. (2013). Kenyamanan Visual melalui Pencahayaan Alami pada Kantor. Jurnal RUAS, 11(2), 10-15.

Vidiyanti, C., Siswanto, R. & Ramadhan, F. (2020). Pengaruh Bukaan Terhadap Pencahayaan Alami dan Penghawaan Alami pada Masjid Al Ahdar Bekasi. Jurnal Arsitektur ZONASI, 3(1), 20-33.

Wati, E., Meukam, P. & Nematchoua, M. K. (2015). Influence of External Shading on Optimum Insulation Thickness of Building Walls in A Tropical Region. ELSEVIER Applied Thermal Engineering, 90, 754-762.

Widiyantoro, H., Muladi, E. & Vidiyant, C. (2017). Analisis Pencahayaan Terhadap Kenyamanan Visual pada Pengguna Kantor. Jurnal Arsitektur, Bangunan, dan Lingkungan, 6(2), 65-70.

Downloads

Published

2022-12-21

How to Cite

Adi, A. R., Afiq, M., & Pamungkas, D. P. (2022). INTEGRATION ANALYSIS OF THERMAL AND DAYLIGHT PERFORMANCE THROUGH THE BUILDING ENVELOPE. Dimensi: Journal of Architecture and Built Environment, 49(2), 87-98. https://doi.org/10.9744/dimensi.49.2.87-98