OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB

SIREGAR Mhd. Akbar Anthony, HIBATULLAH Aflin Tris, MANGKUTO Rizki Armanto3, ATMODIPOERO R. Triyogo4




Abstract


One way to reduce energy consumption in buildings is to use daylighting. However, daylight can cause visual discomfort in the form of glare. Center of Art, Design, and Language (CADL) Institut Teknologi Bandung is a building that has windows on west and east facades, so the probability of glare occurrence is high. In this research, CADL was optimized so that the percentage of time that Daylight Glare Probability below 0.21 (%DGP<0.21) is more than 50% and spatial daylight autonomy with illuminance 150 lux and 50% (sDA150lux,50%) is more than 30%. In the optimization, vertical blinds, horizontal blinds, and curtains were added. Vertical blinds and horizontal blinds were varied by changing the blade’s opening angle and area covering the windows, while curtains were varied only by changing the area covering the windows. The results show that %DGP<0.21 can be increased beyond 50%, but in some rooms, sDA150,50% also decrease below 30%. The most frequent optimum solutions are vertical blinds 75%-60o.


Keywords


Daylight; glare; spatial daylight autonomy.

References


Aries, M. B. C., Veitch, J. A. & Newsham, G. R. (2010). Windows, View, and Office Characteristics Predict Physical and Psychological Discomfort. J. Environ. Psychol., 30(4), p.533 – 541. [CrossRef]

Greenship Building Council Indonesia (2014). Greenship untuk Bangunan Baru Versi 1.2. Jakarta. [CrossRef]

Ghiaus, C. & Inard, C. (2004). Energy and Environmental Issues of Smart Buildings. A Handbook for Intelligent Building, p.26–51. [CrossRef]

Hirning, M. B., Isoardi, G. L. & Cowling, I. (2014). Discomfort Glare in Open Plan Green Buildings. Energy Build., 70, p.427– 440. [CrossRef]

IESNA. (2012). LM-83-12 IES Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). New York: Illuminating Engineering Society of North America. [CrossRef]

Inanici, M. N. (2006). Evaluation of High Dynamic Range Photography as A Luminance Data Acquisition System. Light. Res. Technol., 38(2), p.123–134. [CrossRef]

Jakubiec, J. A. & Reinhart, C. F. (2012). The ‘Adaptive Zone’ – A Concept for Assessing Discomfort Glare throughout Daylit Spaces. Light. Res. Technol., 44(2), p.149–70. [CrossRef]

Mangkuto, R. A., Asri, A. D., Rohmah, M., Soelami, F. X. N. & Soegijanto, R. M. (2016). Revisiting the National Standard of Daylighting in Indonesia: A Study of Five Daylit Spaces in Bandung. [CrossRef]Sol. Energy, 126, p.276 – 290.

Reinhart, C. F., Mardaljevic, J. & Rogers, Z. (2006). Dynamic Daylight Performance Metrics for Sustainable Building Design. Leukos, 3(1), p. 7–31. [CrossRef]

Wienold, J. & Christoffersen, J. (2006). Evaluation Methods and Development of a New Glare Prediction Model for Daylight Environments with the Use of CCD Cameras. Energy Build, 38, p. 743–757. [CrossRef]

Wymelenberg, K. V. D. & Inanici, M. (2014). A Critical Investigation of Common Lighting Design Metrics for Predicting Human Visual Comfort in Offices with Daylight. LEUKOS, 10(3), p. 145–164. [CrossRef]

Yun, G., Yoon, K. C. & Kim, K. S. (2014). The Influence of Shading Control Strategies on the Visual Comfort and Energy Demand of Office Buildings. Energy Build., 84, p. 70 – 85. [CrossRef]