THE EFFECT OF OPENING DISTRIBUTION AREA MODIFICATION ON HORIZONTAL LIGHT PIPE DAYLIGHT PERFORMANCE

Authors

  • Feny Elsiana Petra Christian University
  • Sri Nastiti Ekasiwi Institut Teknologi Sepuluh Nopember
  • I Gusti Ngurah Antaryama Institut Teknologi Sepuluh Nopember

:

https://doi.org/10.9744/dimensi.47.1.19-26

Keywords:

Horizontal Light Pipe, opening distribution area, daylight performance, tropics, office space

Abstract

A deep-plan office building design limits daylight access on the workspace distant from the side window. Horizontal Light Pipe (HLP) is one of the light transport systems that can deliver daylight to these areas. The research aim was to explain and evaluate the effect of HLP’s opening distribution area on daylight performance at deep plan-private office space. The research method was experimental with simulation as a tool. Daylight level and distribution of the base case, HLP with an opening distribution area of 6.6 m2 were compared with the case, HLP with an opening distribution area of 3.41 m2. The results showed that both cases distributed daylight uniformly. A 50% reduction of HLP’s opening distribution area, from 6.6 m2 to 3.41 m2 improved the average Daylight Factor as big as 6.42%. HLP with a smaller opening distribution area can be applied as the main source of daylight on deep-plan office spaces

Downloads

Download data is not yet available.

Author Biographies

Feny Elsiana, Petra Christian University

Department of Architecture

Sri Nastiti Ekasiwi, Institut Teknologi Sepuluh Nopember

Department of Architecture

I Gusti Ngurah Antaryama, Institut Teknologi Sepuluh Nopember

Department of Architecture

References

Alrubaih, M. S., Zain, M. F. M., Alghoul, M. A., Ibrahim, N. L. N., Shameri, M. A., and Elayeb, O. 2013. Research and development on aspects of daylighting fundamentals. Renewable and Sustainable Energy Reviews. 21: 494–505.

Ander, Gregg D. 2003. Daylighting Performance and Design. 2nd Edition. New Jersey: John Wiley & Sons, Inc.

Boubekri, M. 2008. Daylighting, Architecture and Health: Building Design Strategies. United Kingdom: Architectural Press.

Canziani, R., Peron, F., & Rossi, G. 2004. Daylight and energy performances of a new type of light pipe. Energy and Buildings. 36(11): 1163–1176.

Chirarattananon, S., Chedsiri, S., & Renshen, L. 2000. Daylighting through light pipes in the tropics. Solar Energy. 69(4): 331–341.

Courret, G., Scartezzini, J.-L., Francioli, D., & Meyer, J.-J. 1998. Design and assessment of an anidolic light-duct. Energy and Buildings. 28(1): 79–99.

Edwards, L., & Torcellini, P. 2002. A Literature Review of the Effects of Natural Light on Building Occupants. Colorado: National Renewable Energy Laboratory – U.S. Department of Energy.

Egan, M. D. and Olgyay, V. W. 2002. Architectural Lighting. New York: McGraw-Hill Company.

Elsiana, F., Soehartono, F. and Kristanto, L. 2015a. Collaboration of Two Optical Daylighting Systems at Office Building in The Tropics. International Joint Conference SENVAR-iNTA-AVAn 2015. Johor Bahru, Malaysia. 24-26 November 2015. 223-236.

Elsiana, F., Ekasiwi, S.N., Antaryama, I.G.N. 2015b. Daylighting Performance of Horizontal Light Pipe Branching on Open Plan Office Space. Dimensi Journal of Architecture and Built Environment. 42(2): 43-50

Garcia Hansen, V., Edmonds, I. and Hyde, R. 2001. The use of Light Pipes for deep-plan Office Buildings: A case study of Ken Yeang's bioclimatic skyscraper proposal for KLCC, Malaysia. 35th Annual Conference of the Australian and New Zealand Architectural Science Association. New Zealand. 2001.

Heerwagen, Dean. 2004. Passive and Active Environmental Controls: Informing the Schematic Designing of Buildings. New York: McGraw-Hill.

Hien, V. D., Chirarattananon, S., & Luang, K. 2007. Daylighting Through Light Pipe for Deep Interior Space of Buildings with Consideration Heat Gain. Asian Journal on Energy and Environment. 8(1): 461–475.

Kischkoweit-Lopin, M. 2002. An overview of daylighting systems. Solar Energy. 73(2), 77–82.

Kwok, CM and Chung, TM (2008). Computer simulation study of a horizontal light pipe integrated with laser cut panels in a dense urban environment, Lighting Research and Technology 2008 (40), 287–305.

Lechner, Norbert. 2015. Heating, Cooling, Lighting: Sustainable Design Methods for Architects. Fourth edition. New Jersey: John Wiley & Sons, Inc.

Li, D. H. W., & Lam, J. C. 2003. An investigation of daylighting performance and energy saving in a daylit corridor. Energy and Buildings. 35(4): 365–373.

Lomas, K.J. 2007. Architectural Design of an Advanced Naturally Ventilated Building Form. Energy and Buildings. 39(2): 166–181.

L.O. Beltrán, E.S. Lee, and S.E. Selkowitz. 1997. Advanced optical daylighting systems: light shelves and light pipes. Journal of the Illuminating Engineering Society. 26(2): 91-106.

Mogo, B.M. (2005). An Experimental Setup To Evaluate The Daylighting Performance of an Advanced Optical Light Pipe For Deep-Plan Office Buildings (Master Thesis, Texas A&M University, Texas). Retrieved from http://oaktrust.library.tamu.edu/bitstream/handle/1969.1/2522

Steffy, Gary. 2002. Architectural Lighting Design. second edition. New York: John Wiley & Sons, Inc.

Downloads

Published

2021-06-29

How to Cite

Elsiana, F., Ekasiwi, S. N., & Antaryama, I. G. N. (2021). THE EFFECT OF OPENING DISTRIBUTION AREA MODIFICATION ON HORIZONTAL LIGHT PIPE DAYLIGHT PERFORMANCE. Dimensi: Journal of Architecture and Built Environment, 47(1), 19-26. https://doi.org/10.9744/dimensi.47.1.19-26

Issue

Section

Articles